Chapter 8 Drive Parameter Object
124
Parameter
No.
Sub-index
Name
Setting range
Minimum
unit
Default value
Effective
time
occurs, according to
the time to slow down
P05.25
1Ah
Absolute position
rotation mode
mechanical gear
ratio numerator
1~65535
1
1
Immediate
P05.26
1Bh
Absolute position
rotation mode
mechanical gear
ratio denominator
1~65535
1
1
Immediate
P05.27
1Ch
Absolute position
linear mode
position offset
(lower 32 bits)
0~4294967295
1
encoder
unit
0
Immediate
P05.28
1Dh
Absolute position
linear mode
position offset
(upper 32 bits)
0~4294967295
1
encoder
unit
0
Immediate
P05.29
1Eh
The number of
pulses for one
revolution of the
load in absolute
position rotation
mode (lower 32
bits)
0~4294967295
1
encoder
unit
0
Immediate
P05.30
1Fh
The number of
pulses for one
revolution of the
load in absolute
position rotation
mode (upper 32
bits)
0~127
1
encoder
unit
0
Immediate
P05.31
20h
Soft limit function
setting
0: Disable soft limit
1: Enable software
limit immediately after
power-on
2: Enable soft limit
1
0
Immediate