EasyManua.ls Logo

Megmeet M5-N Series - Page 123

Default Icon
170 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Chapter 8 Drive Parameter Object
123
Parameter
No.
Sub-index
Name
Setting range
Minimum
unit
Default value
Effective
time
completed
1: Position deviation
absolute value
smaller than
amplitude of
positioning
completed and
position reference
after filter being 0
2: Position deviation
absolute value
smaller than
amplitude of
positioning
completed and
position reference
being 0
P05.19
14h
Position
positioning
completed range
0~10000
1
comman
d unit
100
Immediate
P05.20
15h
Position close to
signal width
1~32767
1
comman
d unit
100
Immediate
P05.21
16h
Position error
detection range
0~32767
1
encoder
unit
20000
Immediate
P05.22
17h
Position error
alarm selection
0: Valid
1: Invalid
1
0
Immediate
P05.23
18h
Servo shutdown
mode
0: Switch to servo
speed control
according to the
downtime
1: Switch to the
speed control
deceleration stop
1
1
Immediate
P05.24
19h
Servo downtime
0~3000ms
When the PL
(CCWL), NL (.CWL)
1
0
Immediate

Table of Contents

Related product manuals