Operation
optoNCDT 1420
Standard Ceramics, metal
Multi-surface
1
Printed circuit boards (PCB),
hybrid material
Light penetration
1
Plastics (Teflon, POM),
Materials with large penetration
depth of the laser
In the area Signal quality you can switch between four given basic settings (static, balanced, dynamic
and no averaging). You can instantly see the reaction in the diagram and system configuration.
The area System configuration displays the current settings for measuring rate, averaging and RS422 in
blue lettering. Changes to the settings are possible by means of the slide Signal quality or by means of
the tab Settings.
The area Diagram type enables the change between graphical display of the measurement value or the
video signal, each as value time diagram.
i
After programming all the settings are to be stored permanently in a set of parameters. The next time
you turn on the sensor they are available again.
Therefore use the button Save settings.
i
If the sensor starts with user defined measurement setting (setup), see Chap. 7.6.4, changing the signal
quality is not possible.
1) Available for the sensor models ILD1420-10/25/50.