Set Sensor Parameter
optoNCDT 1420
7.4.10 Data Reduction, Output Data Rate
Data reduction Value Instructs the sensor, which data are excluded from the output,
and thus the amount of transmitted data is reduced.
Reduction applies
for
RS422 / Analog The interfaces, which are provided for the sub-sampling, are to
be selected with the checkbox.
You can reduce the measurement output in the sensor if you set the output of every nth measurement value
in the web interface or by command. Data reductions causes that only n-th measurement value is output. The
other measurement values are rejected. The reduction value n can range from 1 (each measurement value)
to 3,000,000. This allows you to adjust slower processes, such as a PLC, to the fast sensor without having to
reduce the measuring rate.
Grey shaded
fields require a
selection.
Value
Dark-bordered
fields require you
to specify a value.