MSB780(X) - User’s Guide
ple:
form<cr>
Write formatted string for FORM: /<cr>
FORM format is OK<cr><lf>
|! 997.34<cr><lf>
|<cr><lf>
wait..OK<cr><lf>
6.14 "form?" Get actual output message format
To get actual output message format, use the form?<cr> command.
Example:
form?<cr>
start>P \RN <end<cr><lf>
send<cr>
997.55<cr><lf>
6.15 “smode” Change the user port start-up operating mode
Use the command smode<cr> to set the port operating mode.
This command is not supported on service port.
The command affects settings on the port currently connected. If you issue the command via
RS-232, the settings will be used only for RS-232.
When connected via service port, the settings of RS-232 or RS-485 may be changed via prior
redirection to the respective port - see commands terminal rs232 or terminal rs485.
Selected output mode is activated after power outages.
Example:
smode<cr>
Select output mode: STOP RUN POLL SEND
New SMODE:RUN<cr>
wait..OK<cr><lf>