Chapter 5 Troubleshooting
147
Error
numbe
r
Message Cause Corrective action
0B2A HD HEATER FUSE
0B35 HD VLT ERR • HD driver voltage 26 V
error detected
0B38 HD DRV V26 • HD driver voltage 26 V ±5
% error
0B3E PCB LOADCELL AD • A problem was detected
with the load cell AD PCB.
0D0B HD CONNECT • A problem was detected
with the head connector
conversion PCB
connection.
0D0C HD THERMIS • Problem detected with
head temperature.
0D0D HDC SPEED • A problem was detected
with head control
0D1C HD BUSY • An error was detected
with the print head
communication.
0D1D HD CMD
0D1E HD DRIVE HOT • High print head
temperature was
detected.
0108 HD TYPE • A problem was detected
with the head control.
012E HD FAILD • There is a head failure.
0186 HDC WAVEFLOW • A problem was detected
with the head control.
B001 Shake the white ink
bottle.
• This is displayed when
filled with white ink. (Each
week)
• Shake the white ink bottle. "Ink
Maintenance"(P. 114)
B002 Replace the flushing
filter.
• This reminds you to
replace the flushing filter
every 30 days.
• Replace the filter. "Flushing Filter
Replacement"(P. 125)
C111 Communication
ERROR (MRL)
• A communication error
was detected between the
control PC and firmware.
• Turn off the control PC, then turn off
the main power. After confirming that
the LAN cable on the rear of the
control PC is properly connected,
turn the power back on.
C801 Target does not exist • Problem detected with
machine connection
• Turn off the control PC, then turn off
the main power. Wait briefly before
turning the control PC and the main
power back on.
• There are improper device
configuration settings. Contact your
local dealer or our service office.
C802 Device composition
ERROR