EasyManua.ls Logo

MIMAKI JFX550-2513 - Power Connection Procedure for JFX600-2513 Machine Number 21 and Later, and the JFX550-2513

MIMAKI JFX550-2513
164 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Connecting the Power
20
Power Connection Procedure for JFX600-2513 Machine Number 21
and Later, and the JFX550-2513
Terminal blocks are attached inside the machine's electrical box.
JFX600-2513JFX600-2513: ×3, JFX550-2513: ×2
A power cable is not included. The user is responsible for providing power cables. Electrical
work between the switchboard and terminal block must be performed by a licensed electrician.
Be sure to only use the following types of cables and circuit breakers.
(1) Cable: VCT-5.5 mm
2
× 3-core (600 V) or UL-AWG10 × 3C (600 V) or equivalent. Outer
sheath external diameter 16 to 20 mm.
(2) Circuit breaker: Single-phase 200 to 240 V AC, 30 A
l
Wire preparation
1
Strip 60 mm of the sheath from the power cable.
60 mm
*1
Black 1: L
Black 2: N
Green/
Yellow: G
*1: Please prepare the wire according to
the particular crimp terminal
specifications.