Connecting the Power
21
2
Attach the allowable types of crimp terminals to the live, neutral, and ground wires (L, N, G).
The sheath must be stripped off the wires to a length that is appropriate for the crimp terminal type
you are using.
For more information regarding allowable crimp terminals, see below.
Terminal block connection details
(1) Model No.: FPSK-30-2P
(2) Manufacturer: TOYOGIKEN
(3) Terminal screws: M4 x 8 (3-part SEMS screw)
Live and neutral wire end preparation
(1) Preparation method: Ring terminal with added insulation.
(2) Shape:
(3) Examples of allowable crimp terminals:
TMEX5.5-4N (NICHIFU)
RAV5.5-S4 (Daido Solderless Terminal Mfg.)
RAV5.5-N4 (Daido Solderless Terminal Mfg.)
RAV5.5-M4 (Daido Solderless Terminal Mfg.)
NBT5.5-S4 (Fuji Terminal Industry)
NBT5.5-SS4 (Fuji Terminal Industry)
Ground wire end preparation
(1) Preparation method: Ring terminal with added insulation.
(2) Crimp terminal stud diameter: φ5 or larger
(3) Examples of allowable crimp terminals:
FN5.5-5 (J.S.T. Mfg.)
N5.5-5 (J.S.T. Mfg.)
Screw tightening torque: 1.8 Nm
Be sure to observe the following three points. Failure to observe the following three points
may result in fire, smoke generation, or electric shock.
(1) Only use power cables and crimp terminals that satisfy the specifications.
(2) Be sure to attach a ring crimp terminal to the end of the power cable.
(3) Secure the ring terminal to the terminal block using the specified tightening torque.
l
Power connection work
1
Make sure that the machine main power supply and the switchboard circuit breaker have been
turned off.
2
Pass each cable through the wiring ports on the right side of the power supply box.