Connecting the Power
18
Power Connection Procedure for JFX600-2513 Machine Numbers 1 to
20
• Power sockets are located on the side of the machine. Three power plugs that fit these power
sockets are included as accessories.
A power cable is not included. The power cable must be prepared by the user. The following
electrical work to connect the switchboard and the sockets must be performed by a licensed
electrician.
• Use the following types of cables, circuit breakers, and plugs:
(1) Cable: VCT-5.5 mm
2
× 3-core (600 V) or UL-AWG10 × 3C (600 V) or equivalent. Outer
sheath external diameter 16 to 20 mm.
(2) Circuit breaker: Single-phase 200 to 240 V AC, 30 A
(3) Included plugs: IEC60309 standard plugs (Straight-insertion type B)
Switchboard
Switchboard
10 mm
13 mm
30 mm
25 mm
l
Plug and cable assembly
1
Make sure that the machine main power supply and the switchboard circuit breaker have been
turned off.