5 - 176
5 OPERATION CONTROL PROGRAMS
[Easy stroke ratio cam]
(1) Cam data can be automatically generated without using the cam data setting of
MT Developer2 by setting the stroke amount and sections.
With the current value per cycle "0" as starting point, automatically generates cam
data from the stroke and cam curve type of each section until the specified end
point (cam axis current value per cycle).
0
(X1,Y1)
(X
5,Y5)
(X
2,Y2)
(X
3,Y3)
(X
4,Y4)
2147483647
-2147483648
Cam axis length per cycle
Stroke: Y[Optional unit]
End point: X
Section 1 Section 3 Section 5
Section 4
Section 2
(Cam reference
position)
(X number of section,Y number of section)