APP - 20
APPENDICES
(2) Transition conditional expressions
Processing time of transition conditional expressions
Classifi-
cations
Symbol Instruction Operation expression
Q173DSCPU/
Q172DSCPU
Unit [
µ
s]
Q173DCPU(-S1)/
Q172DCPU(-S1)
Unit [
µ
s]
Bit device
status
(None)
ON (Normally open
contact)
(Completion of
condition)
M0
1.0 1.0
X100
PX0 3.0 3.0
U3E1\G10000.0 0.5 1.5
!
OFF (Normally
closed contact)
(Completion of
condition)
!M0
1.0 1.5
!X100
!PX0 3.0 3.5
!U3E1\G10000.0 0.5 1.5
Logical
operation
* Logical AND
M0*M1
1.5 2.0
X100*X101
PX0*PX1 5.0 5.5
U3E1\G10000.0*U3E1\G10000.1 1.5 2.5
+ Logical OR
M0+M1
1.5 1.5
X100+X101
PX0+PX1 6.0 7.0
U3E1\G10000.0+U3E1\G10000.1 1.5 2.5
Comparison
operation
==
Equal to
(Completion of
condition)
#0==#1
1.0 1.5
D800==D801
U3E1\G10000==U3E1\G10001 1.5 2.5
#0L==#2L
1.5 2.0
D800L==D802L
U3E1\G10000L==U3E1\G10002L 2.0 2.5
#0F==#4F
2.0 2.5
D800F==D804F
U3E1\G10000F==U3E1\G10004F 3.0 4.0
!=
Not equal to
(Completion of
condition)
#0!=#1
1.5 1.5
D800!=D801
U3E1\G10000!=U3E1\G10001 2.0 2.5
#0L!=#2L
1.5 1.5
D800L!=D802L
U3E1\G10000L!=U3E1\G10002L 1.5 2.5
#0F!=#4F
2.0 2.0
D800F!=D804F
U3E1\G10000F!=U3E1\G10004F 3.0 3.5
<
Less than
(Completion of
condition)
#0<#1
1.5 1.5
D800<D801
U3E1\G10000<U3E1\G10001 2.5 2.5
#0L<#2L
2.0 2.0
D800L<D802L
U3E1\G10000L<U3E1\G10002L 2.5 2.5
#0F<#4F
2.0 2.0
D800F<D804F
U3E1\G10000F<U3E1\G10004F 3.0 3.5

Table of Contents