APP - 19
APPENDICES
Processing time of operation instructions (Continued)
Classifi-
cations
Symbol Instruction Operation expression
Q173DSCPU/
Q172DSCPU
Unit [
µ
s]
Q173DCPU(-S1)/
Q172DCPU(-S1)
Unit [
µ
s]
Synchronous
control
dedicated
function
CAMPSCL
Cam position
calculation
CAMPSCL #0,#2,#14L
(Note-30), (Note-31)
27.5
CAMPSCL D2000,D2002,D2014L
(Note-30), (Note-31)
CAMPSCL U3E1\G10000,U3E1\G10002,
U3E1\G10014L
(Note-30), (Note-31)
32.5
CAMPSCL #0,#2,#14L
(Note-30), (Note-32)
631.0
CAMPSCL D2000,D2002,D2014L
(Note-30), (Note-32)
CAMPSCL U3E1\G10000,U3E1\G10002,
U3E1\G10014L
(Note-30), (Note-32)
644.0
CAMPSCL #0,#2,#14L
(Note-30), (Note-33)
17.0
CAMPSCL D2000,D2002,D2014L
(Note-30), (Note-33)
CAMPSCL U3E1\G10000,U3E1\G10002,
U3E1\G10014L
(Note-30), (Note-33)
22.5
CAMPSCL #0,#2,#14L
(Note-30), (Note-34)
250.0
CAMPSCL D2000,D2002,D2014L
(Note-30), (Note-34)
CAMPSCL U3E1\G10000,U3E1\G10002,
U3E1\G10014L
(Note-30), (Note-34)
327.0
(Note-30): The cam position calculation type is set to the cam axis current value per cycle calculation.
(Note-31): The cam data is in the stroke ratio data format, the cam resolution is 256, and the calculation is performed with the midpoint
(128).
(Note-32): The cam data is in the stroke ratio data format, the cam resolution is 8192, and the calculation is performed with the midpoint
(4096).
(Note-33): The cam data is in the coordinate data format, the coordinates number is 256, and the calculation is performed with the
midpoint (128).
(Note-34): The cam data is in the coordinate data format, the coordinates number is 8192, and the calculation is performed with the