9 COMMON FUNCTIONS
9.11 Event History Function
*1 At start (during analyzing), "0" is displayed when the error processing is executed before fetching the start data No. from the buffer
memory.
When a value outside the setting range is set, a setting value outside the range is displayed.
Event information skipped
When the module errors of the Simple Motion module frequently occur in the intervals shorter than the event history collection
intervals of the CPU module, the event history storage area in the Simple Motion module might be full of error information
which the CPU module has not collected. If a new module error occurs in this state, the Simple Motion module discards the
module error information and outputs the message "*HST.LOSS*" (The event information has been erased.) which indicates
the event information has been erased.
Details of start
(Positioning start No.)
Start No. Occurred data No. Point No. at block start No. at block start
occurrence
Positioning start
(1 to 600)
At start
(Analyzing)
Started positioning No.
(1 to 600)
(Same as start No.)
*1
Not displayed
Operating Data No. in which an error
occurred (1 to 600)
Block start
(7000 to 7004)
At start
(Analyzing)
Started block start No.
(7000 to 7004)
Start data No. of point No. at
block start (1 to 600)
*1
Started block start point No.
(1 to 50)
(Same as point No. at
block start)
Operating Data No. in which an error
occurred (1 to 600)
Started block start point No.
(1 to 50)
Block start point No. in which
an error occurred (1 to 50)
Home position
return
(9001)
At start
(Analyzing)
9001 Not displayed Not displayed
Operating
Fast home
position return
(9002)
At start
(Analyzing)
9002
Operating
Current value
changing
(9003)
At start
(Analyzing)
9003
Operating
Multiple axes
simultaneous
start
(9004)
At start
(Analyzing)
9004 Data No. at start (1 to 600)
*1
Operating Data No. in which an error
occurred (1 to 600)
JOG operation At start
(Analyzing)
9010 Not displayed
Operating
Manual pulse
generator
operation
At start
(Analyzing)
9011
Operating
Speed-torque
control
Mode
switching
9030 to 9042
Operating
Positioning start No. outside the
setting range
Setting value out of the
range