12 DATA USED FOR POSITIONING CONTROL
12.1 Types of Data
379
12
: Always set
: Set as required ("" when not required)
: Setting not possible (If set, the error "Continuous path control not possible" (error code: 1A1EH to 1A20H) will occur at
start.)
: Setting not required (The setting value is invalid. When the value is the default value or within the setting range, there is no
problem.)
*1 Two control systems are available: the absolute (ABS) system and incremental (INC) system.
Positioning data Speed-position switching control Position-speed switching control
[Da.1] Operation
pattern
Independent positioning control
(Positioning complete)

Continuous positioning control 
Continuous path control 
[Da.2] Control method Forward run speed/position
Reverse run speed/position
*1
Forward run position/speed
Reverse run position/speed
[Da.3] Acceleration time No. 
[Da.4] Deceleration time No. 
[Da.6] Positioning address/movement amount 
[Da.7] Arc address 
[Da.8] Command speed 
[Da.9] Dwell time/JUMP destination positioning data No. 
[Da.10] M code/Condition data No./Number of LOOP to
LEND repetitions/Number of pitches

[Da.20] Axis to be interpolated 1 
[Da.21] Axis to be interpolated 2 
[Da.22] Axis to be interpolated 3 
[Da.27] M code ON signal output timing 
[Da.28] ABS direction in degrees 
[Da.29] Interpolation speed designation method 

Table of Contents