EasyManua.ls Logo

Mitsubishi Electric RD77MS2 - Page 467

Mitsubishi Electric RD77MS2
644 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
12 DATA USED FOR POSITIONING CONTROL
12.6 Condition Data
465
12
n: Axis No. - 1
Item Setting value Default
value
Buffer memory
address
Value set with the
engineering tool
Value set with a program
Condition
identifier
[Da.15]
Condition
target
01: Device X 01H 0000H 22100+400n
02: Device Y 02H
03: Buffer memory (1-word) 03H
04: Buffer memory (2-word) 04H
05: Positioning data No. 05H
[Da.16]
Condition
operator
01: ** = P1 01H
02: ** P1 02H
03: ** P1 03H
04: ** P1 04H
05: P1 ** P2 05H
06: ** P1, P2 ** 06H
07: DEV = ON 07H
08: DEV = OFF 08H
[Da.17]
Address
Buffer memory address 0000H 22102+400n
22103+400n
[Da.18]
Parameter 1
Value 0000H 22104+400n
22105+400n
[Da.19]
Parameter 2
Value 0000H 22106+400n
22107+400n
Simultaneously
starting axis
[Da.23]
Number of
simultaneously
starting axes
2: 2 axes 2H 0000H 22108+400n
22109+400n
3: 3 axes 3H
4: 4 axes 4H
[Da.24]
Simultaneously
starting axis
No.1
0: Axis 1 selected
1: Axis 2 selected
2: Axis 3 selected
3: Axis 4 selected
4: Axis 5 selected
5: Axis 6 selected
6: Axis 7 selected
7: Axis 8 selected
8: Axis 9 selected
9: Axis 10 selected
A: Axis 11 selected
B: Axis 12 selected
C: Axis 13 selected
D: Axis 14 selected
E: Axis 15 selected
F: Axis 16 selected
0H
1H
2H
3H
4H
5H
6H
7H
8H
9H
AH
BH
CH
DH
EH
FH
[Da.25]
Simultaneously
starting axis
No.2
[Da.26]
Simultaneously
starting axis
No.3
b15 b0
b7
b8
[Da.16] Condition operator
[Da.15] Condition target
b0b15b16b31
22103 22102
Example)
Buffer memory address
(High-order) (Low-order)
b0b15b16b31
Value
22105 22104
Example)
(High-order) (Low-order)
b0b15b16b31
(Low-order)
Value
22107 22106
Example)
(High-order)
b0b4b8b12b15
[Da.25] [Da.24]
b16b20b24b28b31
[Da.23] [Da.26]

Table of Contents