464
12 DATA USED FOR POSITIONING CONTROL
12.6 Condition Data
The following explains the condition data setting items [Da.15] to [Da.19] and [Da.23] to [Da.26]. (The buffer memory
addresses shown are those of the "condition data No.1 (block No.7000)".)
To perform a high-level positioning control using block start data, set a number between 7000 and 7004 to
the "[Cd.3] Positioning start No." and use the "[Cd.4] Positioning starting point No." to specify a point
number between 1 and 50, a position counted from the beginning of the block.
The number between 7000 and 7004 specified here is called the "block No.".
With the Simple Motion module, up to 50 "block start data" points and up to 10 "condition data" items can be
assigned to each "block No.".
*1 Setting cannot be made when the "Pre-reading start function" is used. If you set any of Nos. 7000 to 7004 and perform the Pre-reading
start function, the error "Outside start No. range" (error code: 19A3H) will occur.
Refer to the following for details.
Page 266 Pre-reading start function
Block No.
*1
Axis Block start data Condition Buffer memory Engineering tool
7000 Axis 1 Start block 0 Condition data (1 to 10) Supports the settings Supports the settings

Axis 16 Condition data (1 to 10)
7001 Axis 1 Start block 1 Condition data (1 to 10)

Axis 16 Condition data (1 to 10)
7002 Axis 1 Start block 2 Condition data (1 to 10)

Axis 16 Condition data (1 to 10)
7003 Axis 1 Start block 3 Condition data (1 to 10)

Axis 16 Condition data (1 to 10)
7004 Axis 1 Start block 4 Condition data (1 to 10)

Axis 16 Condition data (1 to 10)