490
12 DATA USED FOR POSITIONING CONTROL
12.7 Monitor Data
[Md.43] Start data pointer being executed
This area stores a point No. (1 to 50) attached to the start data currently being executed.
This area stores "0" after completion of a positioning operation.
Refresh cycle: Immediate
Reading the monitor value
Monitoring is carried out with a decimal display.
Buffer memory address
Refer to the following for the buffer memory address in this area.
Page 390 Monitor data
[Md.44] Positioning data No. being executed
This area stores a positioning data No. attached to the positioning data currently being executed.
This area stores "0" when the JOG/inching operation is executed.
Refresh cycle: Immediate
Reading the monitor value
Monitoring is carried out with a decimal display.
Buffer memory address
Refer to the following for the buffer memory address in this area.
Page 390 Monitor data
[Md.45] Block No. being executed
When the operation is controlled by "block start data", this area stores a block number (7000 to 7004) attached to the block
currently being executed.
At other times, this area stores "0".
Refresh cycle: At start
Reading the monitor value
Monitoring is carried out with a decimal display.
Buffer memory address
Refer to the following for the buffer memory address in this area.
Page 390 Monitor data
Storage value
1 to 50
Monitor
value
Storage value
1 to 600, 9001 to 9003
Monitor
value
Storage value
7000 to 7004
Monitor
value