500
12  DATA USED FOR POSITIONING CONTROL
12.7  Monitor Data
[Md.120] Reverse torque limit stored value
"[Pr.17] Torque limit setting value", "[Cd.101] Torque output setting value", "[Cd.113] Reverse new torque value", or "[Pr.54] 
Home position return torque limit value" is stored.
 • At the positioning start/JOG operation start/manual pulse generator operation: "[Pr.17] Torque limit setting value" or 
"[Cd.101] Torque output setting value" is stored.
 • When a value is set in "[Cd.22] New torque value/forward new torque value" or "[Cd.113] Reverse new torque value" during 
operation.: "[Cd.22] New torque value/forward new torque value" is stored when "0" is set in "[Cd.112] Torque change 
function switching request". "[Cd.113] Reverse new torque value" is stored when "1" is set in "[Cd.112] Torque change 
function switching request".
 • At the home position return: "[Pr.17] Torque limit setting value" or "[Cd.101] Torque output setting value" is stored. However, 
"[Pr.54] Home position return torque limit value" is stored after the speed reaches "[Pr.47] Creep speed".
Refresh cycle: Immediate
■Reading the monitor value
 • Monitoring is carried out with a decimal display.
 • Buffer memory address
Refer to the following for the buffer memory address in this area.
Page 390 Monitor data
[Md.122] Speed during command
 • This area stores the command speed during speed control mode.
 • This area stores the command speed during continuous operation to torque control mode.
 • "0" is stored other than during speed control mode or continuous operation to torque control mode.
Refresh cycle: Operation cycle (Speed control mode and continuous operation to torque control mode only)
■Reading the monitor value
 • Monitoring is carried out with a decimal display.
 • Buffer memory address
Refer to the following for the buffer memory address in this area.
Page 390 Monitor data
Storage value
1 to 10000 (
× 0.1%)
Monitor 
value
R
Unit conversion
[Md.123] Torque during command
[Md.122] Speed during command
R × 10 
m
m
-1
%
Unit
m
-2
mm/min
-3
inch/min
-3
*
degree/min
0
Unit
Unit conversion table ([Md.122])
Unit conversion table ([Md.123])
pulse/s
Actual 
value
Monitor 
value
*: When "[Pr.83] Speed control 
10 
× multiplier setting for 
degree axis" is valid: "-2"