12 DATA USED FOR POSITIONING CONTROL
12.9 Memory Configuration and Data Process
551
12
(8) Reading data from buffer memory/internal memory to the engineering tool
The following transmission processes are carried out with the [Read from module (Read from RD77MS)] from the engineering
tool.
The "parameters", "positioning data (No. 1 to 600)", "block start data (No. 7000 to 7004)" and "servo parameter" in the
buffer memory/internal memory area are transmitted to the engineering tool via the CPU module.
The following transmission processes are carried out with the [monitor] from the engineering tool.
The "monitor data" in the buffer memory area is transmitted to the engineering tool via the CPU module.
(9) Writing data from the engineering tool to buffer memory/internal memory
The following transmission processes are carried out with the [Write to module (Write to RD77MS)] from the engineering tool.
The "parameters", "positioning data (No. 1 to 600)", "block start data (No. 7000 to 7004)" and "servo parameter" in the
engineering tool are transmitted to the buffer memory/internal memory via the CPU module.
At this time, when [Flash ROM automatic write] is set with the engineering tool, the transmission processes indicated with "(7)
Flash ROM write" are carried out.