APPENDICES APPENDIX
Appendix 3 Compatible Devices with SSCNETIII(/H)
Optional data monitor setting
The following table shows data types that can be set.
Precautions
When FR-A700 series is used, each data is delayed for "update delay time + communication cycle" because of the update
cycle of the inverter. The following table shows the update delay time of each data.
External input signal
Set as the followings to fetch the external input signal (FLS/RLS/DOG) via FR-A700 series.
Set "1: External input signal of servo amplifier" in "[Pr.116] FLS signal selection", "[Pr.117] RLS signal selection", or "[Pr.118]
DOG signal selection".
Set the parameters of the inverter as below. (Otherwise, each signal remains OFF.)
Set the servo parameter of Simple Motion module "Input filter setting (PD11)" to be the same value as the parameter of the
inverter "[Pr.449] SSCNET input filter setting".
Data type Name at FR-A700 series use
Effective load ratio Motor load factor
Load inertia moment ratio Load inertia ratio
Model control gain Position loop gain
Bus voltage Converter output voltage
Encoder multiple revolution counter Absolute position encoder multiple revolution counter
Position feedback Position feedback
Encoder single revolution position Absolute position encoder single revolution position
Data type Update delay time of FR-A700 series
Effective load ratio 12.5 ms
Load inertia moment ratio 56 ms or more (up to 2500 ms)
Model control gain 56 ms or more (up to 2500 ms)
Bus voltage 9.888 ms
Encoder multiple revolution counter 222 s
Position feedback 222 s
Encoder single revolution position 222 s
Setting item Default value Setting value Details
[Pr.178] STF terminal function selection 60 60 Use with the default value.
[Pr.179] STR terminal function selection 61 61 Use with the default value.
[Pr.185] JOG terminal function selection 5 76 Set 76 (Near-point dog).
[Pr.449] SSCNET input filter setting 4 0: None
1: 0.88 ms
2: 1.77 ms
3: 2.66 ms
4: 3.55 ms
Set the input filter setting value at reading an external signal.
Setting item Default value Setting value Details
PD11 Input filter setting 4 0: None
1: 0.88 ms
2: 1.77 ms
3: 2.66 ms
4: 3.55 ms
Set the input filter setting value at reading an external signal.