FX Series Positioning Controllers Parameters 4
4-5
I/O control parameters
30
Program No. specifi-
cation method
0: Program No. 0 (fixed)
0
1: 1 digit of digital switch (0 to 9)
2: 2 digits of digital switch (00 to 99)
3: Specified by special data registers (D9000, D9010)
31
Head No. for digital
switch time division
read input
FX
2N
-20GM: X0 to X67, X372 to X374
0
FX
2N
-10GM: X0 to X3
32
Head No. for digital
switch time division
read output
FX
2N
-20GM: Y0 to Y67
0
FX
2N
-10GM: Y0 to Y5
33
Digital switch read
interval
7 to 100 [ms] (increment: 1 ms) 20
34
RDY output valid-
ness
0: Invalid, 1: Valid 0
35 RDY output No.
FX
2N
-20GM: Y0 to Y67
0
FX
2N
-10GM: Y0 to Y5
36
m code external out-
put validness
0: Invalid, 1: Valid 0
37
m code external out-
put No.
FX
2N
-20GM: Y0 to Y57 (Nine points are occupied.)
0
FX
2N
-10GM: Y0 (Six points are occupied.)
38
m code OFF com-
mand input No.
FX
2N
-20GM: X0 to X67, X372 to X377
0
FX
2N
-10GM: X0 to X3, X375 to X377
39
Manual pulse gener-
ator validness
0: Invalid, 1: Valid (1 pulse generator),
2: Valid (2 pulse generators)
(In FX
2N
-10GM, only "0" or "1" is available.)
0
40
Magnification per
pulse of manual
pulse generator
×
1 to
×
255 1
41
Dividing ratio of
magnification result
FX
2N
-20GM: 2
n
, n = 0 to 7
0
FX
2N
-10GM: Not available
42
Head No. for input of
manual pulse gener-
ator enable signal
FX
2N
-20GM:X2 to X67 (One point is occupied by one
manual pulse generator.)
2
FX
2N
-10GM:X2 to X3 (Nine points are occupied.)
43 to 49

50 ABS interface 0: Invalid, 1: Valid 0
51 ABS input head No.
FX
2N
-20GM:X0 to X66 (Two points are occupied.)
0
FX
2N
-10GM:X0 to X2, X375 to X376
(Two points are occupied.)
52
ABS control output
head No.
FX
2N
-20GM:Y0 to X65 (Three points are occupied.)
0
FX
2N
-10GM:Y0 to Y3
(Three points are occupied.)
53 Step operation 0: Invalid, 1: Valid 0