FX Series Positioning Controllers Parameters 4
4-6
I/O control parameters
54 Step mode input No.
FX
2N
-20GM:X0 to X67, X372 to X377
(One points are occupied.)
0
FX
2N
-10GM:X0 to X3, X375 to X377
(One points are occupied.)
55
56
FWD/RVS/ZRN gen-
eral-purpose input
0:Disables general-purpose inputs.
0
1:Enables general-purpose inputs in AUTO mode.
(Commands by special M are invalid.)
2:Always enables general-purpose inputs.
(Commands by special M are invalid.)
3:Enables general-purpose inputs in AUTO mode.
(Comma.nds by special M are valid.)
4:Always enables general-purpose inputs.
(Commands by special M are valid.)
Table 4.1: Parameter List
PARA.
No.
Item Description ([ ]: unit)
Initial
value