35
Outdoor Station
Technical Specications: Info Module Mx2wire+
Data transfer rate Up to 50 Mbps net (depending on distance)
Interfaces
Ethernet (PoE injector), Mx2wire+ indoor unit, 48-57 V DC, 600 mA
(optional additional supply)
Certicates EMV (EN55022, EN55024, EN61000-6-1, FCC part15B, AS/NZS3548)
Protection class IP65 (DIN EN 60529)
Operating temperature –30 to 50 °C/–22 to 122 °F (DIN EN 50155)
Connecting wire thickness Cable cross-section 0.14 to 2.5 mm2, diameter 0.4 to 1.6 mm
Dimensions (W x H) 99 mm x 99 mm
Note On Labeling
You will nd some PDF templates, which you can print out yourself, on the MOBOTIX
website (www.mobotix.com).
Standard Two-Wire Cabling (Installed in Buildings)
Analog Telephone Line or Bell Wire
•
Cable type: JY, A2Y and YR (telephone and low-voltage cable)
• Very good availability in buildings
• Core diameter 0.6 to 0.8 mm
• Range (at 50 Mbps): 100 m (0.6 mm), 200 m (0.8 mm)
Power Line (Should No Longer Be Live)
• Cable type: NY (installation cable)
• Widespread availability of cables
• Cables must be disconnected from the power supply!
• Wire cross-section max. 1.5 mm2
• Range (at 40 Mbps): 300 m
Safety Warning
Use this product in compliance with the applicable legal regulations. Electrical systems
and equipment may only be installed, modied and maintained by a qualied elec-
trician or under the direction and supervision of a qualied electrician in accordance
with the applicable electrical guidelines.