Maintenance Plan Information
3-4 Manual # 42-02-2P26
Yearly
Controller General
6 month routine as previously stated
Verify screw termination integrity. PC terminals - 7 inch pounds.
Verify integrity of power, isolation transformer, and filter assembly connections.
Fuses: Verify cleanliness and physical integrity. Check for voltage drop across fuse greater
than 1.0 V (AC or DC) - replace if present. MCE fuse locations are labeled - always replace
with the designated type and value.
Air Conditioned Cabinets
6 month routine as previously stated
Load Weighers
6 month routine as previously stated
Lead/Acid Batteries
6 month routine as previously stated
Board-mounted Batteries
These batteries are used to maintain memory over power shutdown.
Measure voltage with controller power off. See manual for specific replacement recom-
mendation. Generally 90% or less of rated voltage (page 2-41).
Car
6 month routine as previously stated
Landing System
6 month routine as previously stated
Power Supplies
6 month routine as previously stated
Brake
6 month routine as previously stated
Rope Gripper
Refer to manufacturer’s recommendations to inspect, clean and lubricate rope gripper.
Cycle power to rope gripper and observe operation.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Motion Control Engineering Nidec Element Series and is the answer not in the manual?

Motion Control Engineering Nidec Element Series Specifications

General IconGeneral
BrandMotion Control Engineering
ModelNidec Element Series
CategoryControl Unit
LanguageEnglish

Related product manuals