4-27
4.1.19 Connecitng the PROVISER Tcmini Series by Toshiba Machine Co., Ltd.
Toshiba Machine PROVISER TCmini Series
Connection method
Setting the communication conditions
Recommended GT and PLC communication settings are as follows.
GT communication settings (Set with the GTWIN configuration settings)
Item Value set
Baud rate 19200 bps
Data length 8 bits
Parity check None
Stop bit 1 bit
Usable devices
Device type No. Remarks
Input X000 to XF7F
Output Y000 to YF7F
Bit
device
Internal relay R000 to R77F
Input X00W to XF7W
Output Y00W to YF7W
Internal relay R00W to R77W
Word
device
General purpose register D000 to DF7F
Each PLC device is coded as follows on the GTWIN. When inputting a device, use these codes.
Display of PLC Display of GTWIN
Bit device R120 R120
R12W RW12
X12W XW12Word device
Y12W YW12