EasyManuals Logo

Napoleon Vector Series Installation Manual

Napoleon Vector Series
156 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #53 background imageLoading...
Page #53 background image
EN
W415-2034 / A / 10.18.19
53
nishing
Non-combustible fi nishing material tight to the frame around the safety barrier (PSB) frame must not project
more than 4” (10cm) from the face of the safety barrier (above the door and sides only). If greater projections
are needed, increase the clearance to the sides and top by 2” (51mm) for every 1” (25mm) projection.
!
WARNING
4" (10cm)
Maximum
protrusion
(must not encroach
on finishing flange)
SAFETY BARRIER
SAFETY
BARRIER
finishing
flange all
around
SIDE VIEW
4"
10cm
Max
1"
25mm
2"
51mm
Non-combustible protrusion

Table of Contents

Other manuals for Napoleon Vector Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Napoleon Vector Series and is the answer not in the manual?

Napoleon Vector Series Specifications

General IconGeneral
Vent TypeDirect Vent
Burner MaterialStainless Steel
WeightVaries by model
ModelVector Series
Fuel TypeNatural Gas or Propane
Viewing AreaVaries by model
Glass TypeCeramic
Ignition SystemElectronic Ignition
DimensionsVaries by model
WarrantyLimited Lifetime Warranty
Remote ControlStandard (eFIRE remote)

Related product manuals