W415-2034 / A / 10.18.19
EN
6
general information
1.1 rates and effi ciencies
Natural Gas Propane
Min. Inlet Gas Supply
Pressure
4.5" w.c. (11mb) 11" w.c. (27mb) 4.5" w.c. (11mb) 11" w.c. (27mb)
Max. Inlet Gas Supply
Pressure
7"* w.c. (17mb) 13” w.c. (32mb) 13” w.c. (32mb) 13” w.c. (32mb).
Manifold Pressure (Under
Flow Conditions)
3.5” w.c. (9mb) 10” w.c. (25mb) 3.5 w.c. (9mb) 10” w.c. (25mb)
LV38-1 / LV50-2 / LV62 / LV74
Single-Sided See-thru
Appliance Type
LV38N-1 LV38P-1 LV38N2-1 LV38P2-1
Fuel Type
Natural Gas Propane Natural Gas Propane
Altitude (FT) 0-4,500
Max. Input (BTU/HR) 30,000 26,500 30,000 26,500
Min. Input (BTU/HR) 21,000 22,000 21,000 22,000
Single-Sided See-thru
Appliance Type
LV50N-2 LV50P-2 LV50N2-2 LV50P2-2
Fuel Type
Natural Gas Propane Natural Gas Propane
Altitude (FT) 0-4,500
Max. Input (BTU/HR) 36,000 31,500 36,000 31,500
Min. Input (BTU/HR) 25,000
Single-Sided See-thru
Appliance Type
LV62N LV62P LV62N2 LV62P2
Fuel Type
Natural Gas Propane Natural Gas Propane
Altitude (FT) 0-4,500
Max. Input (BTU/HR) 42,000 35,000 42,000 35,000
Min. Input (BTU/HR) 29,000 28,000 29,000 28,000
LV50-2
Single-Sided See-thru
Appliance Type
LV74N LV74P LV74N2 LV74P2
Fuel Type
Natural Gas Propane Natural Gas Propane
Altitude (FT) 0-4,500
Max. Input (BTU/HR) 48,000 41,500 48,000 41,500
Min. Input (BTU/HR) 30,000 33,000 30,000 33,000
LV38-1
LV62
LV74
*Maximum inlet pressure not to exceed 13” w.c. (32mb).