CHAPTER 3 SYSTEM DATA PROGRAMMING
– 100 –
NWA-008855-001 Rev.1.0
avch3001.fm
DESCRIPTION DATA
Assign a PAD data to each CS, if required.
Y=08, 09 and 10 should be assigned when the
system is the Integrated Type or the Adjunct
Type (CCIS Interface).
NOTE: For changing these PAD data by
CMAD Y=01/08/09/10, Make Busy/
Make Idle of CS (CME5 Y=3) is not
required.
(1)
(2)
Y=01/08/09/10 Connecting Patterns
000-255: CS No.
See the following table:
T: Transmitter (PS to CS) PAD (dB)/R: Receiver (CS to PS) PAD (dB)
+: Gain
–: Loss
C
CMAD
2ND DATA
PAD DATA (T/R)
Y=01
(CSI-COT/ODT/
DID/IPT)
Y=08
(CSI-DTI/BRT/
PRT/CCT/Virtual
IPT)
Y=09
(CSI-LC/DLC/
ILC)
Y=10
(CSI-CSI)
00 0/0 0/0 0/0 0/0
01 0/+3 0/+3 0/+3 0/+3
02 0/+6 0/+6 0/+6 0/+6
03 0/–3 0/–3 0/–3 0/–3
04 +3/+3 +3/+3 +3/+3 +3/+3
05 +3/+6 +3/+6 +3/+6 +3/+6
06 +3/–3 +3/–3 +3/–3 +3/–3
07 –3/–3 –3/–3 –3/–3 –3/–3
08 +3/0 +3/0 +3/0 +3/0
09 +6/0 +6/0 +6/0 +6/0
10 –3/0 –3/0 –3/0 –3/0
11 –3/0 –3/0 –3/0 –3/0
12 0/–3 0/–3 0/–3 0/–3
13 0/–6 0/–6 0/–6 0/–6
15 0/0 0/0 0/+6 0/+6
D