CHAPTER 3 SYSTEM DATA PROGRAMMING
– 101 –
NWA-008855-001 Rev.1.0
avch3001.fm
DESCRIPTION DATA
Set the kind of CS interface. •
(1)
(2)
Y=24
000-255: CS No.
00 : BS31
15 : BS21/BS21A
Set the sending level of the LCCH from the CS
to the PS.
NOTE: Follow the initial data setting.
When you change the data of CMAD
Y=05/07, contact NEC.
•
(1)
(2)
Y=05
000-255: CS No.
•BS01
01 : 10 mW, –35 dB (Faint)
02 : 10 mW, –15 dB (Average)
15 : 10 mW, 0 dB (Strong) NOTE
• BS21/BS21A/BS31
01 : 10 mW, –15 dB (Faint)
02 : 10 mW, –15 dB (Average)
15 : 10 mW, 0 dB (Strong) NOTE
Set the sending level of the TCH from the CS
to the PS.
•
(1)
(2)
Y=07
000-255: CS No.
•BS01
01 : 10 mW, –35 dB (Faint)
02 : 10 mW, –15 dB (Average)
15 : 10 mW, 0 dB (Strong) NOTE
• BS21/BS21A/BS31
01 : 10 mW, –15 dB (Faint)
02 : 10 mW, –15 dB (Average)
15 : 10 mW, 0 dB (Strong) NOTE
D
CMAD
CSH INITIAL
E