104
S350 Series 8-Port Gigabit Ethernet Smart Managed Pro Switch Models GS308T and GS310TP
9. From the Admin Mode menu, select Enable or Disable.
This selection specifies the administrative mode for port control. You must select Enable
in order for the port to participate in the network. The default is Enable.
10. From the Autonegotiation menu, select Enable or Disable.
This selection specifies the autonegotiation mode for the port. The default is Enable.
Note: After you change the autonegotiation mode, the switch might be
inaccessible for a number of seconds while the new settings take effect.
11. In the Speed field, specify the speed value for the selected port.
Possible field values are as follows:
• Auto. All supported speeds.
• 10. 10 Mbits/second
• 100. 100 Mbits/second
The delimiter characters for setting different speed values are a comma (,), a period (.)
and a space ( ). For you to set the autonegotiation speed, the autonegotiation mode must
be set to Enable. The default is Auto.
Note: After you change the speed value, the switch might be inaccessible for
a number of seconds while the new settings take effect.
12. From the Duplex Mode menu, select the duplex mode for the selected port.
The options are as follows:
• Half. Indicates that the interface supports transmission between the devices in only
one direction at a time.
• Full. Indicates that the interface supports transmission between the devices in both
directions simultaneously.
• Auto. Indicates that speed is set by the auto-negotiation process.
The default is Auto.
Note: After you change the duplex mode, the switch might be inaccessible for
a number of seconds while the new settings take effect.
13. Use the Link Trap menu to specify whether or not to send a trap when link status changes.
The Link Trap menu is enabled by default. However, for LAG interfaces, the menu is
disabled.
14. From the Flow Control menu, select the configuration for IEEE 802.3 flow control.
• Disable. If the port buffers become full, the switch does not send pause frames, and
data loss could occur. This is the default setting.

Table of Contents

Other manuals for NETGEAR GS308T

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the NETGEAR GS308T and is the answer not in the manual?

NETGEAR GS308T Specifications

General IconGeneral
Switch typeManaged
Switch layerL2
Quality of Service (QoS) supportYes
Master (outer) case width214 mm
Master (outer) case height312 mm
Master (outer) case length474 mm
Master (outer) case weight6110 g
Harmonized System (HS) code85176990
Quantity per master (outer) case6 pc(s)
Package typeBox
Package depth270 mm
Package width226 mm
Package height64 mm
Package weight750 g
Cables includedAC
Power connectorDC-in jack
Installed SFP modules quantity0
Basic switching RJ-45 Ethernet ports typeGigabit Ethernet (10/100/1000)
Basic switching RJ-45 Ethernet ports quantity8
StackableNo
Product colorBlack
LED indicatorsActivity, Link, Power
Country of originChina
10G support-
Multicast protocolsIGMP
Input current1 A
DC input voltage12 V
MAC address table- entries

Related product manuals