3.67 EDH0162En1040 06/99
MM4005 LP List program
Usage IMM PGM MIP
Syntax xxLP
Parameters
Description xx
[int] Program number.
Range xx 1 to 127.
Units xx
None.
Defaults xx Missing: Error F.
Out of range: Error F.
Floating point: Error A.
Description This command reads a specified program from RAM and sends it to the
selected communication port (RS232C or IEEE488). During the transmission
no other command should be sent to the controller.
To read a program from the non-volatile memory, first use the MP com-
mand to download its content in RAM.
Returns Program listing.
Errors A Unknown message code.
F Program number incorrect.
G Program does not exist.
I Unauthorized command in programming mode.
Rel. Commands MP Download EEPROM to RAM.
Example MP | Copy programs from EEPROM to RAM.
3LP | List program number 3.
1PA0
| Program listing.
|
|
|