VRA53801-R.3609.A
- M9 -
LS-50
2. 13 ICE4 Advanced (Digital-ICE quad Advanced) Host processing
"ICE4 Advanced" is generic name of Digital-ICE, Digital-ROC, Digital-GEM, and Revelation.
Digital-ICE :Detect defects (such as damages, dusts, dirt, etc), and restore the image data
that was deteriorated by these defects. Scanning is performed by visible
light of RGB and infrared light, then by getting the information on defects
from the infrared images, RGB image is restored based on such information.
This is available for Kodachrome but depending on images, slight blurs occur in
some cases.
Digital-ROC :Correct the color deterioration of lms and color seepage
Digital-GEM :Control and smooth graininess of lms.
Revelation   Change contrast per area, and optimize the dynamic range to get close to physical
appearance.
This is used to describe the details under the following conditions: against light;
insufcient light volume of speedlight; overexposure
2. 14 Resolution and resizing process
Maximum (optical) resolution : 4000dpi
The body (scanner) can perform pixel-skipping scanning in both main and sub scanning directions.
Pixel skipping Pitch:  1 1/44  corresponding to 4000dpi 90dpi
However, the scanner does not perform pixel skipping regarding odd-number Pitch except the
full Pitch.
The nal scan is performed with relatively higher resolution than the resolution of the nal output
image, and the driver software processes the averaging.
      Final resolution      Scanning Pitch
      4000 , 2000dpi 1
      2000 , 1000dpi 1
      1000 , 500dpi    2AVON
       500 , 250dpi   2
       250 , 125dpi 4
125 , 90dpi 8
2.15 Thumbnail scan
SA-21, SA-30
The body (scanner) xes the scan block unit, and the inner motor of SA feeds lms to scan
images.
Resolution: 97dpi (Pitch 41
Averaging: ON (8-pixel average in the main scanning direction)
AF position: is set when outputting thumbnail or set to the latest AF address in the past (192
address when AF is not performed)
Thumbnail can be automatically performed by detecting the insertion of lms.