VRA53801-R.3609.A
- A41 ・ -
LS-50
・Scanning position accuracy
Select "Run" on the main menu, then choose "Mechanical Precision Test" and "Precision the Scanning Position" from
the pulldown menus.
In case of NG: Replace the mecha-block unit.
Inspection result on scanning position accuracy
・Color registration
Select "Run" on the main menu, then choose "Mechanical Precision Test" and "Color Registration" from the pulldown
menus.
In case of NG: Clean the optical system and clean/apply grease on the carriage advance mechanism, or replace the
mecha-block unit.
Inspection result on color registration