Boot Options
150
Basic System Configuration Guide
3HE 11010 AAAC TQZZA Edition: 01
5.4 Accessing the CLI
There are three ways to access management of the 7705 SAR:
console connection
Telnet connection
SSH connection
To access the CLI to configure the software for the first time, follow these steps:
1. Ensure that the CSM is installed and power to the chassis is turned on. The
7705 SAR software then automatically begins the boot sequence.
2. When the boot loader and BOF image and configuration files are successfully
located, establish a router connection (console session).
5.4.1 Console Connection
To establish a console connection, you will need the following:
an ASCII terminal or a PC running terminal emulation software set to the
parameters shown in Table 21
a standard serial cable with a male DB9 connector
Figure 9 displays an example of the Console port on a 7705 SAR front panel.
Table 21 Console Configuration Parameter Values
Parameter Value
Baud Rate 115 200
Data Bits 8
Parity None
Stop Bits 1
Flow Control None