Basic System Configuration Guide System Management
Edition: 01 3HE 11010 AAAC TQZZA 305
config>system>ptp>clock# exit
config>system>ptp# exit
config>system# sync-if-timing begin
config>system>sync-if-timing# ref1
config>system>sync-if-timing>ref1# source-ptp-clock 1
config>system>sync-if-timing>ref1# no shutdown
config>system>sync-if-timing>ref1# exit
The following display shows a basic IEEE 1588v2 PTP configuration:
ALU-1>config>system>ptp># info
#--------------------------------------------------
echo "System IEEE 1588 PTP Configuration"
#--------------------------------------------------
system
ptp
clock 1 create
clock-type ordinary slave
source-interface "ptp loop"
clock-mda 1/2
domain 0
no dynamic-peers
priority1 128
priority2 128
profile ieee1588-2008
ptp-port 1
anno-rx-timeout 3
log-anno-interval 1
log-sync-interval -6
unicast-negotiate
peer 1
description "Peer to Boundary Clock"
ip-address 10.222.222.10
exit
peer 2
description "ToGM"
ip-address 192.168.2.10
exit
no shutdown
exit
no shutdown
exit
exit
exit
6.10.6.4 Configuring QL Values for SSM
Use the following syntax to configure the quality level (QL) values for
Synchronization Status Messaging (SSM).
CLI Syntax: config>system>sync-if-timing
abort