Basic System Configuration Guide System Management
Edition: 01 3HE 11010 AAAC TQZZA 303
ALU-1>config>system>sync-if-timing>ref1# source-port 1/1/1
MINOR: CLI The sync-if-
timing must be in edit mode by calling begin before any changes can be made.
MINOR: CLI Unable to set source port for ref1 to 1/1/1.
ALU-1>config>system>sync-if-timing>ref1#
6.10.6.2 Configuring Timing References
The following example shows the command usage:
Example: config>system# sync-if-timing
config>system>sync-if-timing# begin
config>system>sync-if-timing# ref1
config>system>sync-if-timing>ref1# source-port 1/1/1
config>system>sync-if-timing>ref1# no shutdown
config>system>sync-if-timing>ref1# exit
config>system>sync-if-timing# ref2
config>system>sync-if-timing>ref2# source-port 1/1/2
config>system>sync-if-timing>ref2# no shutdown
config>system>sync-if-timing>ref2# exit
config>system>sync-if-timing>commit
The following displays the timing reference parameters:
ALU-1>config>system>sync-if-timing# info
----------------------------------------------
ref-order ref2 ref1
ref1
source-port 1/1/1
no shutdown
exit
ref2
no shutdown
source-port 1/1/2
exit
6.10.6.3 Configuring IEEE 1588v2 PTP
Use the following CLI syntax to configure basic IEEE 1588v2 PTP parameters.
CLI Syntax: config>system>ptp
clock clock-id [create]
clock-mda mda-id
clock-type {ordinary [master | slave] |
boundary | transparent-e2e}
domain domain-value
dynamic-peers