Basic System Configuration Guide Boot Options
Edition: 01 3HE 11010 AAAC TQZZA 155
5.6 Accessing MPT Radios Connected to a
7705 SAR
The 9500 MPR MPT Craft Terminal Launcher (MCT Launcher) is an application that
runs on a Windows PC. By connecting the PC to the 7705 SAR out-of-band
Management (Mgmt) port on the active CSM, local MPT radios can be configured
and monitored using this application.
To reach both local and remote MPT radios, the PC must be connected to an
Ethernet data port on an adapter card and requires a service access point (SAP) to
enable in-band management. An IES service together with a local DHCP server
configured on the 7705 SAR provides this capability to on-site technicians.
The following output shows a configuration example for a local DHCP server and an
IES service.
A:SAR18>config>port# info
----------------------------------------------
description “Craft Port for MW Technicians”
ethernet
exit
no shutdown
----------------------------------------------
*A:SAR18>config>router>dhcp>server# info
----------------------------------------------
description “DHCP server to serve on-site microwave technician pc”
pool “craft_pool” create
description “Single address pool”
use-gi-address
subnet 192.168.1.0/30 create
options
subnet-mask 255.255.255.252
default-router 192.168.1.1
exit
address-range 192.168.1.2 192.168.1.2
exit
exit
no shutdown
----------------------------------------------
*A:SAR18>config>service>ies>if$ info
----------------------------------------------
address 192.168.1.1/30
dhcp
server 192.168.1.1
gi-address 192.168.1.1
no shutdown
exit
local-dhcp-server “craft_dhcp_server”
sap 1/3/2 create
exit
----------------------------------------------