EasyManua.ls Logo

Nokia 7705 - 6.4.6.8 PTP Boundary Clock for Time of Day;Phase Recovery; 6.4.6.9 PTP End-to-End Transparent Clock for Time of Day;Phase Recovery

Nokia 7705
538 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Basic System Configuration Guide System Management
Edition: 01 3HE 11010 AAAC TQZZA 247
6.4.6.8 PTP Boundary Clock for Time of Day/Phase Recovery
The following equipment supports PTP boundary clock capability for time of day/
phase recovery:
all fixed platforms listed in Table 25
all cards listed in Table 26
The 7705 SAR-8 can support up to six boundary clocks and the 7705 SAR-18 can
support up to eight boundary clocks. The fixed platforms can each support one
boundary clock. PTP boundary clocks that recover time of day/phase from a grand
master clock or another boundary clock can be used as a reference for the router
system time clock, providing high-accuracy OAM timestamping and measurements
for the following equipment:
7705 SAR-8
7705 SAR-18
7705 SAR-A
7705 SAR-Ax
7705 SAR-H
7705 SAR-Hc
7705 SAR-M
7705 SAR-W
7705 SAR-Wx
7705 SAR-X
Each PTP boundary clock for time of day/phase is configured for a specific slot where
the adapter card or port will perform the boundary clock function. On fixed platforms,
with the exception of the 7705 SAR-X, this slot is always 1/1. On the 7705 SAR-X,
this slot is always either 1/2 or 1/3. Each boundary clock is also associated with a
loopback or system address for the router.
6.4.6.9 PTP End-to-End Transparent Clock for Time of Day/Phase
Recovery
PTP end-to-end transparent clock for time of day/phase recovery is supported on the
following:
the fixed platforms listed in Table 25
2-port 10GigE (Ethernet) module