Boot Options
154
Basic System Configuration Guide
3HE 11010 AAAC TQZZA Edition: 01
5.5 Accessing the Management Port on a
7705 SAR-W
The 7705 SAR-W supports in-band and out-of-band node management
communication. The RJ-45 Management port provides physical access for
out-of-band communication. When the Inband/Local switch on the chassis is in the
Inband position, the management interface on the CSM processor connects to the
internal data port on the datapath for in-band management, and the external RJ-45
Management port is disabled.
The internal data port is identified in the CLI as vrtl-mgmt, and as port 1/1/6 in
SNMP. The vrtl-mgmt port only supports access mode and Epipe service, where the
port has encap-type null, dot1q, or qinq with VLAN 0.
See the “Installation and Provisioning” section in the 7705 SAR-W Chassis
Installation Guide for details on setting up in-band management connections.