System Management
336
Basic System Configuration Guide
3HE 11010 AAAC TQZZA Edition: 01
Description This command creates a system name string for the device.
For example, system-name parameter ALU-1 for the name command configures the device
name as ALU-1.
ABC>config>system# name ALU-1
ALU-1>config>system#
Only one system name can be configured. If multiple system names are configured, the last
one encountered overwrites the previous entry.
The no form of the command reverts to the default value.
Default The default system name is set to the chassis serial number which is read from the backplane
EEPROM.
Parameters system-name — the system name as a character string. Allowed values are any string
up to 32 characters long composed of printable, 7-bit ASCII characters. If the string
contains spaces, the entire string must be enclosed within double quotes.
power-feed-monitoring
Syntax [no] power-feed-monitoring {A | B | C}
Context config>system
Description This command suppresses power feed monitoring and alarms on the secondary input power
feed of a chassis when that power feed is not in use. Use this command when monitoring and
raising alarms on the unused power input is not required. Suppressing monitoring and alarms
on an unused input power feed results in the following:
• logging of input power feed failures is suppressed
• any alarms that have been raised on an unused power feed are cleared when the no
power-feed-monitoring command is applied to that power feed
• in the Power Feed Information output of the show>chassis command, the status of the
unused input power feed appears as “not monitored”
• for chassis that use the Status LED to indicate alarms, the Status LED will be lit green if
no other alarm conditions exist; for chassis that have alarm LEDs, the critical alarm LED
will be unlit if no other critical alarm conditions exist. For the 7705 SAR-Hc, the alarm
LED is unlit if no other alarm condition exists.
Power feed monitoring and alarming is enabled by default.
Default power-feed-monitoring
Parameters A — corresponds to the first input power feed
B — corresponds to the second input power feed