Basic System Configuration Guide System Management
Edition: 01 3HE 11010 AAAC TQZZA 387
anno-rx-timeout
Syntax anno-rx-timeout number-of-timeouts
no anno-rx-timeout
Context config>system>ptp>clock
config>system>ptp>clock>ptp-port
Description This command defines the number of announce timeouts that need to occur on a PTP slave
port or boundary clock port in slave mode before communication messages with a master
clock are deemed lost and the master clock is considered not available. One timeout in this
context is equal to the announce interval in seconds, calculated using the logarithm 2^log-
anno-interval.
The no form of this command returns the configuration to the default value.
Default 3
Parameters number-of-timeouts — specifies the number of timeouts that need to occur before
communication messages to a master clock are deemed lost and the master clock is
considered not available
Values 2 to 10
clock-mda
Syntax clock-mda mda-id
no clock-mda
Context config>system>ptp>clock
Description This command configures the adapter card slot that performs the IEEE 1588v2 clock
recovery. On the 7705 SAR-M, 7705 SAR-H, 7705 SAR-Hc, 7705 SAR-A, 7705 SAR-Ax,
7705 SAR-W, and 7705 SAR-Wx, this slot is always 1/1. On the 7705 SAR-X, this slot is
always either 1/2 or 1/3.
This command is only available when the clock-id parameter value is 1 to 16.
The no form of this command clears the clock recovery adapter card.
Default n/a
Parameters mda-id — slot/mda