EasyManua.ls Logo

Oberheim Matrix-12 - Selecting an Envelope; Basic ENV X Operation

Oberheim Matrix-12
194 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Page
1
Selecting
an
ENVELOPE
Pressing
the
ENV
X
button
in
the
SINGLE/MULTI
PATCH
PAGE
SELECT
section
will
give
the
display:
SELECT
ENVELOPE
FROM
1
TO
5
While
this
message
is
being
displayed,
the
LED
in
X
SELECT
will
flash
on
and
off,
prompting
you
to
select
one
of
the
five
available
Envelopes.
The
CURRENT
PAGE
section
of
the
PROGRAMMER
display
will
show
the
Envelope
that
was
last
selected.
You
may
then...
...
press
an
X
SELECT
button
from
1
to
5
to
select
that
Envelope
...
or
press
the
ENV
X
button
again
to
select
the
Envelope
that
was
selected
previously-the
one
displayed
under
CURRENT
PAGE.
This
feature
adds
speed
when
selecting
an
Envelope
to
be
worked
with.
Once
you
have
selected
an
Envelope,
it
will
be
displayed
in
PAGE
MODIFIER.
At
this
point
you
are
able
to
program
its
parameters.
You
may
also
switch
among
the
five
Envelopes
with
the
X
select
buttons
if
none
of
the
Lower
display
functions
are
underlined.
Basic
ENVX
Operation
Since
the
five
Envebpes
are
identical,
their
parameters
are
covered
together
in
the
following
discussion:
DELA
Y
This
is
the
time
that
the
Envelope
will
wait
before
starting
its
cycle.
Amount
value
range
is
from
0
to
63.
A
setting
of
0
means
no
DELA
Vand
the
Envelope
will
start
its
cycle
with
the
Attack
stage
the
moment
it
is
triggered.
63
is
the
maximum
Delay
time.
ATTACK
Afterthe
DELAYstage
is
completed,
this
stage
sets
the
amount
of
time
it
will
take
for
the
Envelope
to
reach
its
output
level (set
in
the
AMP
parameter).
Range:
0
to
63.0 =
instant
ATTACK.
63
is
the
maximum
Attack
time.
DECAY
Afterthe
Attack
stage
finishes
and
the
Envelope's
output
level
is
reached,
the
Envelope
will
then
start
to
decrease.
DEC
A
/sets
the
time
it
will
take
for
the
Evelope's
output
to
decrease
to
the
level
set
by
SUSTAIN.
Range:
0
to
63.0
»instant
DECAY.
63
is
the
maximum
Decay
time.
SUSTAIN
The
Decay
stage
will
decrease
the
output
of
the
Envelope
until
the
Sustain
level
is
reached.
SUSTAIN,
then,
sets
the
Envelope's
output
level
while
you
are
holding
a
key
or
keys
on
the
Keyboard.
It
is
important
for
you
to
understand
that
SUSTAINIs
not
a
time
parameter
but
determines
the
Envelope's
output
if
a
key
or
keys
are
still
held
after
the
DELAY,
ATTACKand
DECA
/stages.
Matrix-12
Owner's
Manual
129

Table of Contents

Related product manuals