If
SUSTAIN
is
set
to
its
maximum,
there
will
be
no
decrease
in
the
Envelope's
output
until
the
keys
you
are
holding
are
let
go.
In
this
case,
DECA
Yhas
no
effect.
The
envelope
will
remain
at
whatever
the
Sustain
level
is
until
the
keys
you
are
holding
are
released.
Range:
0
to
63.0
«
no
Sustain
level
and
if
keys
are
held
for
the
duration
of
the
DECA
/stage,
the
Envelope
will
return
to
its
0
output
level
(its
starting
point).
63
=
maximum
Envelope
output
level
and
is
maintained
while
keys
are
held.
RELEASE
After
you
have
let
go
of
the
key
or
keys,
the
Envelope
will
continue
to
decrease
in
output
level
until
0
level
is
reached.
The
RELEASE
parameter
sets
the
time
for
this
to
occur.
VALUE
X
range
is
from
0
to
63 where
0
returns
the
Envelope
instantly
to
its
0
level
and
63
is
the
maximum
Release
time.
AMP
"Amplitude"
-
As
we
mentioned
earlier
in
this
section,
the
Envelopes'
primary
function
is
to
increase
and
decrease
a
control
signal's
output
level
over
a
time
period.
This
output
level
is
set
by
the
AMP
parameter.
In
other
words,
AMP
determines
how
much
the
Envelope
as
a
modulation
source
will
affect
its
destination.
Range
is
from
0
to
63.
Envelope
MODES
We
already
know
that
when
an
Envelope
receives
a
trigger,
it
will
start
its
cycle.
How
the
Envelope
completes
its
cycle
is
selected
from
the
three
parameters
displayed
in
the
top
window
of
PAGE
MODIFIER.
The
normal
operating
mode
of
an
Envelope
is
to
complete
its
cycle
while
a
key
or
keys
are
being
held
down
during
the
DELA
/,
ATTACK,
DECA
Yand
SUSTAIN
stages
of
its
cycle.
After
the
keys
are
let
go,
the
flELE4SEstage
finishes
the
Envelope.
Holding
a
key
or
keys
is
called
"Gating"
-
the
Envelope
in
its
normal
mode
needs
a
Gate
to
complete
its
cycle.
If
none
of
the
three
parameters
in
the
top
display
is
selected,
the
Envelope
is
said
to
be
in
its
normal
operating
mode.
If
the
keys
are
let
go
at
any
time
before
the
SUSTAINlevel
is
reached
(even
during
DELAY
or
ATTACK)
t\he
Envelope
goes
immediately
to
its
RELEASE
stage.
Variations
in
this
simple
operating
mode
are
selected
from
the
following
parameters:
RESET
This
mode
causes
the
Envelope
to
start
its
cycle
from
the
very
beginning
every
time
the
Voice
receives
a
new
trigger.
This
means
if
an
Envelope
that
is
in
mid-cycle
receives
a
new
trigger,
it
will
start
all
over
again
from
0
output
level
the
moment
the
new
trigger
is
received.
This
is
true
for
all
triggers
-from
keys
being
played,
External
Triggers
or
LFO
triggers.
In
the
normal
mode,
if
an
Envelope
receives
a
new
trigger
at
some
point
in
its
cycle,
it
will
start
over
but
not
from
0.
It
will
continue
from
the
point
in
its
cycle
where
the
new
trigger
was
received
at
its
current
output
level
set
by
AMP.
130
Matrix-12
Owner's
Manual

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Oberheim Matrix-12 and is the answer not in the manual?

Oberheim Matrix-12 Specifications

General IconGeneral
BrandOberheim
ModelMatrix-12
CategorySynthesizer
LanguageEnglish

Related product manuals