XZAC4074 Service Manual 1-21
1.10.2 Peripheral errors
Problem
Solution
Audio
Check that the Audio cable is connected correctly or replace the
loudspeakers.
CD-ROM
If the CD-ROM does not read:
Change the CD used for testing. If the CD-ROM still does not read, the
problem is in the CD-ROM.
If the CD-ROM is not recognized:
Check correct setting of the jumpers on the motherboard and
compatibility.
CD-ROM error:
Check that the pins of connector CN9 are not damaged.
Check that the IDE cable is connected correctly or replace it.
No sound from the CD:
Check that the Line Out cable is connected correctly.
Compact Flash
The CF Card is not detected:
Check correct setting of the jumpers on the motherboard and
compatibility.
The CF Card is not read
Check that the pins of the connector are not damaged or replace the CF
Card.
COM
Check that the jumpers of the COM port are set correctly.
Check that connector CN9 is connected correctly or replace it.
Check the I/O board
Printer
Check that connector CN9 pin is connected correctly or replace it.
Check the I/O board.
USB
Check that connector CN9 and the USB cables are connected correctly
or replace them.
Check the I/O board.
Check the USB board fitted to the front.
Check the front panel USB board-motherboard connection cable.
DIO
Check that connector CN9 is connected correctly or replace it.
Check the I/O board.
LAN
Check that the LAN cable is connected correctly.
Check the LAN ID code.
Check the I/O board.
Check the motherboard.

Table of Contents