8
Precautions for Correct Use
Precautions for Correct Use
Installation
Mount the product vertically on a wall or on a DIN track (optional) with the product's longer sides upright.
The material of the wall has to be nonflammable such as a metal plate.
Main Circuit Power Supply
Confirm that the rated input voltage of the Inverter is the same as AC power supply voltage.
Error Retry Function
Do not come close to the machine when using the error retry function because the machine may abruptly
start when stopped by an alarm.
Be sure to confirm the RUN signal is turned off before resetting the alarm because the machine may
abruptly start.
Non-Stop Function at Momentary Power Interruption
Do not come close to the machine when selecting restart in the non-stop function at momentary power
interruption selection (b050) because the machine may abruptly start after the power is turned on.
Operation Stop Command
Provide a separate emergency stop switch because the STOP key on the Digital Operator is valid only when
function settings are performed.
When checking a signal during the power supply and the voltage is erroneously applied to the control input
terminals, the motor may start abruptly. Be sure to confirm safety before checking a signal.
Product Disposal
Comply with the local ordinance and regulations when disposing of the product.

Table of Contents

Other manuals for Omron 3G3JX

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Omron 3G3JX and is the answer not in the manual?

Omron 3G3JX Specifications

General IconGeneral
Model3G3JX
CategoryInverter
Control MethodV/f control
Input Frequency50/60 Hz
Communication InterfaceRS-485 (optional)
Operating Temperature-10 to 50°C
Humidity20 to 90% RH (non-condensing)
Enclosure RatingIP20
Input Voltage200 to 240 V AC
Output VoltageThree-phase 200 to 240 V AC
Output Frequency400 Hz
ProtectionOvercurrent, Overvoltage, Undervoltage, Overheat
CommunicationRS-485
Braking UnitBuilt-in
Power Range0.1 to 15 kW
Cooling MethodFan-cooled
Storage Temperature-20°C to +65°C
AltitudeUp to 1000 m