EasyManua.ls Logo

Omron 3G3JX

Omron 3G3JX
262 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
4-54
4-2 Function Mode
4
Functions
External Trip
Use this function to trip the Inverter according to the peripheral system conditions.
When the EXT terminal is turned on, E12 is displayed and the Inverter trips to stop output.
Allocate 12 (EXT) to the desired multi-function input.
(Example 1) 0 Hz start
Starts at 0 Hz regardless of motor rotation
speed. The retry wait time is ignored.
An overcurrent trip may occur with this start at
a high motor speed.
(Example 2) Frequency pull-in restart
After the FRS terminal is turned off, the motor
frequency is matched and a frequency pull-in
restart is performed without stopping the motor.
If an overcurrent trip occurs, extend the retry
wait time.
FW
FRS
Motor rotation
speed
0
Free
running
0 Hz start
FW
FRS
Motor rotation
speed
Free running
b003
0
Frequency pull-in star
t
Data Symbol Function name Status Description
12 EXT External trip
ON
Sets the motor to free-run status by shutting off
output.
OFF The motor is in normal operation.
Related functions C001 to C005
RUN commands
FW and RV
EXT terminal
Motor rotation
speed
RS terminal
Alarm output
terminal
Free running

Table of Contents

Other manuals for Omron 3G3JX

Related product manuals