7-18
7-5 Options
7
Specifications
Operating Environment
3-phase
400 V AC
3G3AX-
DL4004
Fig. 1
0.4 66 90 98 85 56 72 5.2 × 8 M4 0.8 1.25 mm
2
min.
3G3AX-
DL4007
0.75 66 90 98 95 56 72 5.2 × 8 M4 1.1 1.25 mm
2
min.
3G3AX-
DL4015
1.5 66 90 98 115 56 72 5.2 × 8 M4 1.6 2 mm
2
min.
3G3AX-
DL4022
2.2 86 100 116 105 71 80 6 × 9 M4 2.1 2 mm
2
min.
3G3AX-
DL4037
3.7 86 100 116 120 71 80 6 × 9 M4 2.6 2 mm
2
min.
3G3AX-
DL4055
5.5 111 100 138 110 95 80 7 × 11 M4 3.6 3.5 mm
2
min.
3G3AX-
DL4075
7.5 111 100 138 115 95 80 7 × 11 M4 3.9 3.5 mm
2
min.
Inverter input
power supply
Model
Figure
No.
Applicable
Inverter
capacity (kw)
Dimensions (mm) Bmax: coil dimensions
Weight
(kg)
Wire size
WDHBXY C K
Ambient temperature -10°C to 50°C
Humidity 20% to 90% RH (with no condensation)
Vibration 15 kW max. 5.9 m/s
2
max. (0.6G) 10 to 55 Hz
22 kW max. 2.0 m/s
2
max. (0.2G) 10 to 55 Hz
Location At a maximum altitude of 1,000 m; indoors (without corro-
sive gases or dust)

Table of Contents

Other manuals for Omron 3G3JX

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Omron 3G3JX and is the answer not in the manual?

Omron 3G3JX Specifications

General IconGeneral
Model3G3JX
CategoryInverter
Control MethodV/f control
Input Frequency50/60 Hz
Communication InterfaceRS-485 (optional)
Operating Temperature-10 to 50°C
Humidity20 to 90% RH (non-condensing)
Enclosure RatingIP20
Input Voltage200 to 240 V AC
Output VoltageThree-phase 200 to 240 V AC
Output Frequency400 Hz
ProtectionOvercurrent, Overvoltage, Undervoltage, Overheat
CommunicationRS-485
Braking UnitBuilt-in
Power Range0.1 to 15 kW
Cooling MethodFan-cooled
Storage Temperature-20°C to +65°C
AltitudeUp to 1000 m