EasyManua.ls Logo

Omron 3G3JX - Page 243

Omron 3G3JX
262 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
App-4
Appendix-1 Parameter List
Appendix
Multi-step speed, Jogging
A021
Multi-step speed
reference 1
0.0/Starting frequency to Max. frequency
0.0
Yes Hz
A022
Multi-step speed
reference 2
0.0
A023
Multi-step speed
reference 3
0.0
A024
Multi-step speed
reference 4
0.0
A025
Multi-step speed
reference 5
0.0
A026
Multi-step speed
reference 6
0.0
A027
Multi-step speed
reference 7
0.0
A028
Multi-step speed
reference 8
0.0
A029
Multi-step speed
reference 9
0.0
A030
Multi-step speed
reference 10
0.0
A031
Multi-step speed
reference 11
0.0
A032
Multi-step speed
reference 12
0.0
A033
Multi-step speed
reference 13
0.0
A034
Multi-step speed
reference 14
0.0
A035
Multi-step speed
reference 15
0.0
A038 Jogging frequency 0.00/Starting frequency to 9.99 6.00 Yes Hz
A039
Jogging stop
selection
00: Free-run stop
01: Deceleration stop
02: DC injection braking stop
00 No
Parameter
No.
Function name
Monitor or data range
(Digital Operator)
Default
setting
Changes
during
operation
Unit
Set
value
* 2nd control is displayed when SET (08) is allocated to one of from C001 to C005.