3 Operation and Test Run
3 - 28
Multi-function Compact Inverter 3G3MX2-EV2 User’s Manual (I666-E1)
Parameter No.
Function name
Set value
Default data
Unit
A001
1st Frequency Reference
Selection
02: Digital Operator
02
A002
1st RUN Command Selec-
tion
02: Digital Operator
02
H003
1st Motor Capacity
0.1/0.2/0.4/0.55/0.75/
1.1/1.5/2.2/3.0/3.7/4.0/
5.5/7.5/11.0/15.0/18.5
Maximum applicable
motor capacity
kW
H004
1st Motor Pole Number
2/4/6/8
10 to 48: Do not set.
4
pole
b012
1st Electronic Thermal Level
0.20 Rated current to
1.00 Rated current
Rated current
A
b087
STOP Key Selection
00: Enabled
00