EasyManua.ls Logo

Omron 3G3MX2-A2002-EV2 - Page 159

Omron 3G3MX2-A2002-EV2
612 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
3
Operation and Test Run
3 - 29
Multi-function Compact Inverter 3G3MX2-EV2 User’s Manual (I666-E1)
Parameter No.
Function name
Data range
Default data
Unit
F001
Output Frequency Setting/
Monitor
0.00, Starting Frequency to
1st Maximum Frequency
6.0
Hz
F004
RUN Direction Selection
00: Forward
01: Reverse
00
d001
Output Frequency Monitor
0.00 to 590.00
Hz
d003
RUN Direction Monitor
F: Forward
o: Stop
r: Reverse
Key
Data display example
Description
Press the Mode key for 1 second or more to display the d001
data “0.00”.
Press the RUN key.
The RUN LED lights and the frequency reference monitor value
is displayed on the data display.
No-load Run
3
3-4 Operation Items for Test Run

Table of Contents